I will design foam fire suppression system per nfpa 11 and nfpa 16
NFPA Certified Fire Protection Consultant
Level 1
Has met certain performance criteria and shows strong potential in the marketplace.
Highly Responsive
Known for exceptionally quick replies
About this Gig
Foam system design done right sized, calculated, and code referenced.
I'm a certified Fire & Life Safety consultant (CFPS, CFPE) with suppression design experience across the USA, ME and Pakistan.
FOAM Systems I design:
- Low, medium & high expansion foam NFPA 11
- Foam-water sprinkler & deluge systems NFPA 16
- Fixed roof & floating roof tank protection (foam chambers, subsurface injection)
- Dike & bund area protection
- Loading racks, pump rooms & flammable liquid storage
- Foam monitors & hose stations
Deliverables:
- System layout & P&ID / schematic
- Foam concentrate quantity & application rate calculations
- Proportioning system selection (bladder tank, balanced pressure, inline inductor)
- Hydraulic calculations
- Equipment schedule & bill of materials
- Submittal-ready DWG + PDF with code references
Designs account for foam type and concentration (1% / 3% / 6%, AR-AFFF, fluorine-free transitions) per the hazard and your local requirements.
Before ordering: message me with the hazard type (fuel, tank size, area), site plan, and water supply data so I can confirm scope and quote.
Building type:
Commercial
•
Industrial
•
Infrastructure
Software:
AutoCAD
•
Revit MEP
•
SprinkCAD
•
Elite Fire
•
Bluebeam Revu
Delivery style preference
Please inform the freelancer of any preferences or concerns regarding the use of AI tools in the completion and/or delivery of your order.
My Portfolio
FAQ
Which foam concentrates do you design with?
Per your hazard and supplier including fluorine-free foams (SFFF) where AFFF is being phased out. If you have a preferred manufacturer, I design around their listed equipment.
Can you design for flammable liquid storage tanks?
Yes, Fixed roof, internal and external floating roof tanks per NFPA 11, including chamber count, application rates, and discharge duration.
Do you provide stamped drawings?
I provide design drawings and calculations per NFPA standards. Where your jurisdiction requires a licensed engineer's stamp, your engineer of record can review and submit my design.
What information do you need to start?
Hazard description (fuel type, tank dimensions or protected area), site/floor plan, water supply data, and any project specs or insurer requirements.
4 reviews for this Gig
| (4) | ||
| (0) | ||
| (0) | ||
| (0) | ||
| (0) |
Rating Breakdown
- Seller communication level
- Quality of delivery
- Value of delivery
Sort By
D 
danielchoo75

Singapore
Awesome A+++
$100-$200
Price
4 days
Duration
Helpful?S sorchandareith

Cambodia
Happy to work with her. Supportive and full of experience
$200-$400
Price
1 day
Duration
A 
Seller's Response
Helpful?J juanarredondo88

United States
Very helpful and patient. Great communication skills.
Helpful?M mlv234

Canada
patient and willing :)
Helpful?
4 reviews for this Gig
| (4) | ||
| (0) | ||
| (0) | ||
| (0) | ||
| (0) |
Rating Breakdown
- Seller communication level
- Quality of delivery
- Value of delivery
Sort By
D 
danielchoo75

Singapore
Awesome A+++
$100-$200
Price
4 days
Duration
Helpful?S sorchandareith

Cambodia
Happy to work with her. Supportive and full of experience
$200-$400
Price
1 day
Duration
A 
Seller's Response
Helpful?J juanarredondo88

United States
Very helpful and patient. Great communication skills.
Helpful?M mlv234

Canada
patient and willing :)
Helpful?

