I will design ul 300 and nfpa 96 kitchen fire suppression
fire alarm design, fire alarm shop drawings, NFPA 72 plans, AutoCAD drafting,
About this Gig
Need UL 300 & NFPA 96 wet chemical kitchen fire suppression shop drawings that pass local AHJ and Fire Marshal submittals?
I specialize in drafting permit ready commercial kitchen hood fire suppression layouts, piping schematics, and submittal packages following NFPA 96, NFPA 17A, and UL 300 standards for restaurants, ghost kitchens, food halls, and institutional facilities.
Systems Covered: Ansul R 102 / Piranha, Pyro Chem Kitchen Knight II, Range Guard, Buckeye Kitchen Mister, and Amerex KP.
Services Included:
- Complete Hood, Duct & Appliance Lineup Layouts
- Nozzle Aiming Points, Flow Point Calculations & Pipe Sizing
- Cylinder/Tank Location, Actuation Lines & Detection Cable Routing
- Manual Pull Station Placement & Gas/Electric Fuel Shutoff Interlocks
- Single Line Riser / Isometric Piping Diagrams
- Delivery in AutoCAD (.DWG) and Print Ready PDF Formats
Why US Kitchen Contractors Work With Me:
- AHJ Precision: Fully compliant with NFPA 17A/96 and manufacturer design manuals.
- Fast Revisions: Prompt updates for plan check markup comments.
Please message me with your kitchen equipment layout, hood dimensions, and system brand before placing an order
Project scale:
House
Building type:
Residential
•
Commercial
•
Office & workspace
Delivery style preference
Please inform the freelancer of any preferences or concerns regarding the use of AI tools in the completion and/or delivery of your order.
FAQ
Which wet chemical system manufacturers do you support?
I design layouts based on major UL 300 pre engineered system manufacturer manuals, including Ansul (R-102 & Piranha), Pyro Chem (Kitchen Knight II), Range Guard, Buckeye (Kitchen Mister), and Amerex (KP).
What information is included on the shop drawings?
Drawings include hood and exhaust duct dimensions, appliance lineup measurements, nozzle positioning (appliance, plenum, and duct protection), pipe sizing, cylinder/tank placement, detection fusible link locations, manual pull station heights, and automatic fuel/power shutoff interlock details.
Do you calculate nozzle flow points?
Yes. I calculate total system flow points based on appliance hazard types, hood size, and duct parameters to verify cylinder size and piping limitations per the manufacturer design manual.
Do you provide a PE stamp or certified installer sign off?
I prepare the complete shop drawing submittal package and piping details ready for permit review. If your local AHJ strictly requires an local wet stamp or certified installer seal, your local fire suppression distributor/installer can review and seal these drawings.

